A handheld pulse oximeter with masimo set measure through motion and low perfusion pulse oximetry in a study published in journal of clinical anesthesiology comparing three pulse oximetry technologies masimo set demonstrated the highest sensitivity and specificity in identifying desaturation events during conditions of motion and low perfusion1.
Masimo rad 8 pulse oximeter sensors.
Lncs sensors are intended for hospitals that prefer to minimize clinician user interface change when upgrading their pulse oximetry to masimo set and do not anticipate adopting rainbow technology.
This section covers the use and cleaning of masimo sensors and patient cables.
To date there have been five published cchd screening studies representing a total of 241 239 infants that used exclusively masimo set pulse oximeters and sensors 6 10 two of which 59 876 subjects were the.
See instructions for use for full prescribing information including indications contraindications warnings and precautions.
Featuring masimo set pulse oximetry proven accurate during motion and low perfusion.
General knowledge of pulse oximetry and an understanding of the features and functions of the rad 8 are a prerequisite for its proper use.
Other transducers sensors and cables may affect rad 8 performance.
Before use of any sensor carefully read the sensor s directions for use.
Masimo set was the first pulse oximetry technology to receive fda 510 k clearance in the labeling to screen newborn patients for critical congenital heart disease cchd.
Lncs is intended for hospitals that prefer to minimize clinician user interface change when upgrading their pulse oximetry to masimo set.
Lncs reusables lncs or low noise cabled sensors are cabled sensors.
The home mode feature allows for safe and accurate monitoring and trending while at home and this pulse ox machine has radnet and radlink interface.
Lncs sensors are compatible with masimo set pulse oximeters and nellcor sensor compatible instruments without oximax.
Use only masimo sensors and cables with the rad 8 pulse oximeter.
Lncs sensors are cabled with a db9 connector compatible with lnc.
These algorithms allow the distinction between arterial and venous signal during motion and low perfusion by identifying and isolating the non arterial and venous noise spo 2 left peak.
Federal usa law restricts this device to sale by or on the order of a physician.
Serial output to compatible devices and nurse call interface.
Rad 8 s compact lightweight design is ideal for acute and alternate care settings including long term care facilities homecare and sleep labs.
Conventional pulse oximetry uses the standard red over infrared algorithm to provide spo 2 while masimo set uses that conventional algorithm but has added four other algorithms that all run in parallel.